								Double Beam UV VIS Spectrophotometer TRDUV-604

Double Beam UV VIS Spectrophotometer TRDUV-604

Double Beam UV VIS Spectrophotometer TRDUV-604 is a double-beam optical system with blazed holographic gratings. It has a sophisticated power protection system, a wavelength range of 190 to 1100 nm, a bandwidth of 2 nm, and an accuracy of 0.3 nm. it performs admirably in qualitative testing with a photometric display range of 0.0–200.0 % T, -0.301 to 4.000 A, 0.000 to 9999 C, and an accuracy of 0.3 % T (0 to 100 % T), 0.002A (0 to 0.5A), and 0.004A, (0.5A to 1A). It comes with a USB interface..

$2206.00
Qty :

Specifications

Monochromatic type Czerny turner
Focal length 160 mm
Wavelength Range 190 to 1100nm
Band Width 2 nm
Wavelength Accuracy ±0.3 nm
Wavelength Repeatability ≤0.01 nm
Photometric Display Range 0.0 to 200 .0% T, -0.301 to 4.000 A, 0.000 to 9999 C
Photometric Accuracy ±0.3% T(0 to 100%T), ±0.002A(0 to 0.5A), ±0.004A(0.5A to 1A)
Photometric Repeatability 0.15% T(0 to 100%T), ±0.001A(0 to 0.5A) / ±0.002A(0.5A to 1A)
Photometric Mode T,A,C,E
Stray Light ≤0.03% τ (220nm NaI, 360nm NaNO2)
Stability 0.0005A/h@500 nm
Detector Import Silicon Photodiode
Scanning speed Fast-medium-slow
Power Requirement AC220V±22 50Hz±1Hz,200W
Baseline Flatness ≤0.002A(200 to 1090 nm)
Grating 1200 lines/mm
Drifting ≤0.0009 Abs/30 min (250 nm and 500 nm after 2h warm-up)
Dimensions(W×D×H) 74×63×45 Cm
Weight 35    Kg

Features

  •   The blazed hologram gratings are used in the dual-beam UV VIS Spectrophotometer
  •   Designed with an 8-inch color touch screen, advanced user interface, powerful functions, and simple operation
  •   The equipment performs well in qualitative and quantitative testing due to its powerful functions, such as
  •   Examine the entire spectrum
  •   Linear regression analysis
  •   Extensive frequency searching
  •   Direct reading with concentration
  •   Persistence of time-based kinetics
  •   Measurement of multiple wavelengths
  •   A sophisticated power protection system is built into the equipment
  •   It has a large internal memory and can hold test results, image data, regression analysis, and correction data. As a result, when turned on, it performs a quick initialization
  •   Connected with printer, which can print results or draw curves from spectral scanning, fixed wavelength time-based scanning, and linear repression
  •    The device can be connected to a PC via a USB, which not only improves performance in data testing and spectrum scanning but also expands the memory to save more testing results